Unit of Measure

Specifications

Dimensional Drawing

N/A
STL Series, Force Sensing Tension Links for Anchor and Chain Shackles
a1100.jpg

Load Capacity

N/A 24000 lb

Material

N/A Stainless Steel 17-4, H-1025 (Standard)

Connector Type

N/A Connector Permanently Attached Cable

Shackle Size

N/A 1-1/4 Inch

A - Length

N/A 1-3/4 in

B - Width

N/A 1-7/8 in

C - Diameter

N/A 3-1/16 in

D - Diameter

N/A 0.873 in

E - Length

N/A 2-11/16 in

F - Length

N/A 1-7/16 in

G - Length

N/A 3-3/8 in

L - Overall Length

N/A 11 in

M - Length

N/A 7-1/2 in

R - Radius

N/A 1 in

T - Diameter

N/A 1.438 in

Weight

N/A 12 lb

Safety Factor

N/A 3.0

Performance Specs

Overload without Zero Shift

N/A 150%

Bridge

N/A Full bridge 350 Ohm (Nominal)

Excitation

N/A 12 V AC (Maximum) 12 V DC (Maximum)
Output Signal1 N/A 2-mV/V (Nominal) 2-mV/V (Standardized Output)

Non-Repeatability

N/A 0.10% FS

Non-Linearity

N/A 0.25% FS

Hysteresis

N/A ±0.15% FS

Temp Effects (on Zero)

N/A 0.003% FS / °F

Temp Effects (on Output)

N/A 0.003% load / °F (Nominal)
Zero Balance2 N/A ±2% FS (Nominal)

Static Overload

N/A 150% without zero or open shift

Electrical Specifications

Receptacle

N/A PT02H-10-6P

Mating Plug

N/A PT06A-10-6S (SR)

     Function

N/A Pin

     (+) Excitation

N/A A

     (-) Excitation

N/A D

     (+) Signal

N/A B

     (-) Signal

N/A C

Cable

N/A #20(26x34) AWG., rubber insulation, shielded, rubber jacket, 4-Conductor (Standard Cable)

     Function 

N/A Wire Code

     (+) Excitation 

N/A Red

     (-) Excitation 

N/A Black

     (+) Signal 

N/A Green

     (-) Signal 

N/A White

General Information

N/A The Strainsert Tension Links are superior performance sensors, for use in weighing and force measuring applications.

Its sensing element consists of a strain gage bridge circuit internally installed in a small hole along its longitudinal axis. This unique arrangement provides a most effective means for the protection and sealing of the strain gage circuit while minimizing the adverse effects of extraneous torsional and flexural loads.

Tension Links can be modified for underwater use.

  • 1 Exact output provided with calibration data. (Standardized outputs are optional).
  • 2 Prior to loading, it is necessary to initially/periodically null the zero load output to account for any residual offset.