Compression Load Cells measure forces in compression only.

Measurement ranges:
250 to 2.5 million lbs.

Model FL7.5C(C)-2SPK shown

Unit of Measure
Items
Strainsert Compression Load Cell.jpg

Compression Load Cells

Strainsert Compression Load Cell.jpg

Compression Load Cells

Strainsert Compression Load Cell.jpg

Compression Load Cells

Strainsert Compression Load Cell.jpg

Compression Load Cells

Strainsert Compression Load Cell.jpg

Compression Load Cells
Load Capacity N/A 250 lb N/A 500 lb N/A 1,000 lb N/A 2,500 lb N/A 5,000 lb
Type of Flat Load Cells N/A Compression
Rated Output N/A 2-mV/V (Nominal) 2-mV/V (Std. Output) N/A 2-mV/V (Nominal) 2-mV/V (Std. Output) N/A 2-mV/V (Nominal) 2-mV/V (Std. Output) 3-mV/V (Nominal) 3-mV/V (Std. Output) N/A 2-mV/V (Nominal) 2-mV/V (Std. Output) 3-mV/V (Nominal) 3-mV/V (Std. Output) N/A 2-mV/V (Nominal) 2-mV/V (Std. Output) 3-mV/V (Nominal) 3-mV/V (Std. Output)
Configuration N/A Single Bridge N/A Single Bridge N/A Dual Bridge Single Bridge N/A Dual Bridge Single Bridge N/A Dual Bridge Single Bridge
Non-Linearity N/A General Purpose ±0.25% F.S. Precision ±0.15% F.S. N/A General Purpose ±0.25% F.S. Precision ±0.15% F.S. N/A General Purpose ±0.25% F.S. Precision ±0.15% F.S. N/A General Purpose ±0.25% F.S. Precision ±0.15% F.S. N/A General Purpose ±0.25% F.S. Precision ±0.10% F.S.
Connector Type N/A Connector Permanently Attached Cable
A - Diameter N/A 9/16 in N/A 9/16 in N/A 1/2 in N/A 9/16 in N/A 11/16 in
B - Diameter N/A 1-1/4 in N/A 1-1/4 in N/A 1-5/16 in N/A 1-1/2 in N/A 1-7/16 in
C - Diameter N/A 2-1/2 in
D - Diameter N/A 2-11/16 in
E - Length N/A 3-23/32 in
F - Height N/A 15/16 in
G - Width N/A 2-13/16 in
H - Height N/A 1-1/16 in
J - Length N/A 1/16 in
K - Outside Diameter N/A 7/32 in N/A 7/32 in N/A 7/32 in N/A 1/4 in N/A 1/4 in
k - Inside Diameter N/A 1/8 in N/A 1/8 in N/A 1/8 in N/A 5/32 in N/A 5/32 in
Number of Hold Down Bolt Holes N/A 4
L - Diameter N/A 1-13/16 in N/A 1-13/16 in N/A 1-7/8 in N/A 1-7/8 in N/A 1-7/8 in
M - Length N/A 1/32 in
N - Depth of Hole N/A 1/8 in N/A 1/8 in N/A 1/8 in N/A 5/32 in N/A 5/32 in
Lifting Holes - Threads N/A NONE
Lifting Holes - BC. Diameter N/A NONE
Weight N/A 0.6 lb N/A 0.6 lb N/A 0.6 lb N/A 0.6 lb N/A 1.2 lb
y - Full Load Deflection N/A 0.00027 Inch N/A 0.00054 Inch N/A 0.00082 Inch N/A 0.00114 Inch N/A 0.00076 Inch
K - Spring Rate N/A 920000 lb/in N/A 920000 lb/in N/A 1220000 lb/in N/A 2200000 lb/in N/A 6600000 lb/in
We - Load Cell Without External Weights N/A 0.028 lb N/A 0.028 lb N/A 0.023 lb N/A 0.040 lb N/A 0.135 lb
fc' - Natural Frequency N/A 18000 cps N/A 18000 cps N/A 22800 cps N/A 23300 cps N/A 22000 cps
Wp - Load Cell With External Weights N/A 0.25 lb N/A 0.5 lb N/A 1.0 lb N/A 2.5 lb N/A 5.0 lb
fp' - Natural Frequency N/A 5700 cps N/A 4150 cps N/A 3420 cps N/A 2930 cps N/A 3560 cps
Accuracy N/A  
Material of Construction N/A Aluminium Alloy N/A Aluminium Alloy N/A Aluminium Alloy N/A Aluminium Alloy N/A Alloy Steel
     Non-Linearity N/A General Purpose ±0.25% FS Precision ±0.15% FS N/A General Purpose ±0.25% FS Precision ±0.15% FS N/A General Purpose ±0.25% FS Precision ±0.15% FS N/A General Purpose ±0.25% FS Precision ±0.15% FS N/A General Purpose ±0.25% FS Precision ±0.10% FS
     Hysteresis N/A General Purpose ±0.20% FS Precision ±0.15% FS N/A General Purpose ±0.20% FS Precision ±0.15% FS N/A General Purpose ±0.20% FS Precision ±0.15% FS N/A General Purpose ±0.20% FS Precision ±0.15% FS N/A General Purpose ±0.15% FS Precision ±0.10% FS
     Non-Repeatability N/A ±0.05% FS
Environmental N/A  
     Compensated Range N/A 60 to 150 ºF
     Effect on Zero N/A ±0.0035% FS/°F
     Effect on Output N/A ±0.0030% Load/°F (Nominal)
Electrical N/A  
     Excitation Voltage N/A 15V AC or DC (Maximum)
     Bridge Resistance N/A 350 Ohms (Nominal)
     Zero Balance1 N/A ±2% FS (Nominal)
     Insulation Resistance N/A 10,000 Megaohms (Minimum)
Mechanical N/A  
     Safe Static Overload without Zero Shift N/A 200%FS
     Safe Static Overload without Output Shift N/A 200%FS
     Safe Static Overload without Structural Failure N/A 250%FS
  • 1 Prior to loading, it is necessary to initially/periodically null the zero load output to account for any residual offset.