Metric Universal Load Cells measure forces in both tension and compression.

Measurement ranges:
±1.1 to ±1,780 KN

Model FL100UM(C)-2SGKB shown
Items
Metric Universal Load Cell

Metric Universal Load Cells

Metric Universal Load Cell

Metric Universal Load Cells

Metric Universal Load Cell

Metric Universal Load Cells

Metric Universal Load Cell

Metric Universal Load Cells

Metric Universal Load Cell

Metric Universal Load Cells
Load Capacity N/A 1.1 kN N/A 2.2 kN N/A 4.5 kN N/A 11.1 kN N/A 22.2 kN
Type of Flat Load Cells N/A Universal Metric
Rated Output N/A 2-mV/V (Nominal) 2-mV/V (Std. Output) N/A 2-mV/V (Nominal) 2-mV/V (Std. Output) N/A 2-mV/V (Nominal) 2-mV/V (Std. Output) 3-mV/V (Nominal) 3-mV/V (Std. Output) N/A 2-mV/V (Nominal) 2-mV/V (Std. Output) 3-mV/V (Nominal) 3-mV/V (Std. Output) N/A 2-mV/V (Nominal) 2-mV/V (Std. Output) 3-mV/V (Nominal) 3-mV/V (Std. Output)
Configuration N/A Single Bridge N/A Single Bridge N/A Dual Bridge Single Bridge N/A Dual Bridge Single Bridge N/A Dual Bridge Single Bridge
Non-Linearity N/A General Purpose ±0.25% F.S. Precision ±0.15% F.S. N/A General Purpose ±0.25% F.S. Precision ±0.15% F.S. N/A General Purpose ±0.25% F.S. Precision ±0.15% F.S. N/A General Purpose ±0.25% F.S. Precision ±0.15% F.S. N/A General Purpose ±0.25% F.S. Precision ±0.10% F.S.
Connector Type N/A Connector Permanently Attached Cable
Hole Type N/A Threaded Loading Hole Thru Hole
A - Diameter N/A 17.5 mm N/A 17.5 mm N/A 17.5 mm N/A 17.5 mm N/A 16.7 mm
B - Diameter N/A 36.5 mm
C - Diameter N/A 63.5 mm
D - Diameter N/A 66.7 mm
E - Length N/A 93.7 mm
F - Height N/A 23.8 mm
G - Width N/A 71.4 mm
H - Height N/A 25.4 mm
K - Outside Diameter N/A 8.73 mm
k - Inside Diameter N/A 5.56 mm
Number of Hold Down Bolt Holes N/A 8
L - Diameter N/A 49.2 mm
M - Length N/A 0.8 mm
N - Depth of Hole N/A 7.9 mm
T - Hole N/A 10.53 -0/+0.02 Thru Hole M10x1.5 N/A 10.53 -0/+0.02 Thru Hole M10x1.5 N/A 10.53 -0/+0.02 Thru Hole M10x1.5 N/A 10.53 -0/+0.02 Thru Hole M10x1.5 N/A 12.53 -0/+0.02 Thru Hole M12x1.25
Lifting Holes - Threads N/A NONE
Lifting Holes - BC. Diameter N/A NONE
Weight N/A 0.3 kg N/A 0.3 kg N/A 0.3 kg N/A 0.3 kg N/A 0.5 kg
Material of Construction N/A Aluminum Alloy N/A Aluminum Alloy N/A Aluminum Alloy N/A Aluminum Alloy N/A Alloy Steel
Accuracy N/A  
     Non-Linearity N/A General Purpose ±0.25% FS Precision ±0.15% FS N/A General Purpose ±0.25% FS Precision ±0.15% FS N/A General Purpose ±0.25% FS Precision ±0.15% FS N/A General Purpose ±0.25% FS Precision ±0.15% FS N/A General Purpose ±0.25% FS Precision ±0.10% FS
     Hysteresis N/A General Purpose ±0.20% FS Precision ±0.15% FS N/A General Purpose ±0.20% FS Precision ±0.15% FS N/A General Purpose ±0.20% FS Precision ±0.15% FS N/A General Purpose ±0.20% FS Precision ±0.15% FS N/A General Purpose ±0.15% FS Precision ±0.10% FS
     Non-Repeatability N/A ±0.05% FS
Environmental N/A  
     Compensated Range N/A 60 to 150 ºF
     Effect on Zero N/A ±0.0035% FS/°F
     Effect on Output N/A ±0.0030% Load/°F (Nominal)
Electrical N/A  
     Excitation Voltage N/A 15V AC or DC (Maximum)
     Bridge Resistance N/A 350 Ohms (Nominal)
     Zero Balance1 N/A ±2% FS (Nominal)
     Insulation Resistance N/A 10,000 Megaohms (Minimum)
Mechanical N/A  
     Safe Static Overload without Zero Shift N/A 200%FS
     Safe Static Overload without Output Shift N/A 200%FS
     Safe Static Overload without Structural Failure N/A 250%FS
Mating Plug N/A PT06A-10-6S (SR)
     Function N/A Pin
     (+) Excitation N/A A
     (-) Excitation N/A D
     (+) Signal N/A B
     (-) Signal N/A C
Cable N/A #20(26x34) AWG., rubber insulation, shielded, rubber jacket, 4-Conductor (Standard Cable)
     Function  N/A Wire Code
     (+) Excitation  N/A Red
     (-) Excitation  N/A Black
     (+) Signal  N/A Green
     (-) Signal  N/A White
  • 1 Prior to loading, it is necessary to initially/periodically null the zero load output to account for any residual offset.