N/A
|
Overload without Zero Shift |
N/A 150% |
Overload without Failure |
N/A 300% (Minimum) |
Bridge |
N/A Full bridge 350 Ohm (Nominal) |
Excitation |
N/A 12 V AC (Maximum) 12 V DC (Maximum) |
| Output Signal1 | N/A 2-mV/V (Nominal) 2-mV/V (Standardized Output) |
Non-Repeatability |
N/A ±0.15% FS (Nominal) |
Non-Linearity |
N/A ±0.50% FS (Nominal) |
Hysteresis |
N/A ±0.50% FS (Nominal) |
Service Temp Range |
N/A to 150 °F |
Temp Effects (on Zero) |
N/A 0.005% FS / °F (Nominal) |
Temp Effects (on Output) |
N/A 0.008% load / °F (Nominal) |
| Zero Balance2 | N/A ±2% FS (Nominal) |
Load Capacity |
N/A 800,000 lb |
Material |
N/A Stainless Steel 17-4, H-1025 (Standard) |
A - Width of Center Loading Section |
N/A 6-1/4 in |
B - Width of Clevis Support Section |
N/A 3-1/2 in |
C - Length of Pin/Bolt Reduced Section, Instrumented Zone |
N/A 1-3/4 in |
Dp - Nominal Pin Diameter |
N/A 8.000 in |
E - Active Length of Pin |
N/A 16-3/4 in |
F - Clevis Pin Head Length |
N/A 2.25 in |
H - Width of Keeper Plate Slot |
N/A 25/32 in |
J - Depth of Keeper Plate Slot |
N/A 1-3/8 in |
Lp - Overall Length of Pin |
N/A 20-3/4 in |
W - Allowance for Retaining Ring Installation |
N/A 1-3/4 in |
Keeper Plates |
N/A SPA-600-112-1-A |
Connector Type |
N/A Axial Connector Permanently Attached Axial Cable |
Receptacle |
N/A PTIH-10-6P |
Mating Plug |
N/A PT06A-10-6S (SR) |
Function |
N/A Pin |
(+) Excitation |
N/A A |
(-) Excitation |
N/A D |
(+) Signal |
N/A B |
(-) Signal |
N/A C |
Cable |
N/A #20(26x34) AWG., rubber insulation, shielded, rubber jacket, 4-Conductor (Standard Cable) |
Function |
N/A Wire Code |
(+) Excitation |
N/A Red |
(-) Excitation |
N/A Black |
(+) Signal |
N/A Green |
(-) Signal |
N/A White |
|
N/A
Clevis Load Pins are strain gage transducers developed by Strainsert (U.S. Patent No. 3,695,096). They are manufacured utilizing the internal strain gage process perfected by Strainsert since 1960. We offer precision force measurement by simply replacing existing clevis pins. |