Features
N/A
Actuator/Hydraulic Cylinder Load Pins are strain gage transducers developed by Strainsert (U.S. Patent No. 3,695,096). They are manufacured utilizing the internal strain gage process perfected by Strainsert since 1960. We offer precision force measurement by simply replacing existing hydraulic cylinder load pins. |
Specifications
Dimensional Drawing |
N/A
![]() Loading zoom SPHC Force Sensing Clevis Pin ![]() Loading zoom |
Material |
N/A Stainless Steel 17-4, H-1025 (Standard) |
Load Capacity |
N/A 6000 lb |
Dp - Nominal Pin Diameter |
N/A 0.750 in |
Connector Type |
N/A Axial Connector Permanently Attached Axial Cable |
Load Angle Relative to Base Bracket |
N/A
0° (Standard) Customer Defined (±Alpha) |
Cylinder Bore Diameter |
N/A 2 Inch2-1/2 Inch |
A - Width of Center Loading Section |
N/A 0.94 in |
B - Width of Clevis Support Section |
N/A 0.72 in |
C - Length of Pin Reduced Section, Instrumented Zone |
N/A 0.31 in |
CE - Length |
N/A 2.38 in |
Ec - Width of Rod End Clevis |
N/A 2.75 in |
F - Clevis Pin Head Length |
N/A 2.00 in |
FL - Length |
N/A 1.88 in |
G - Clevis Support Section |
N/A 0.47 in |
H - Allowance for Retaining Ring |
N/A 0.44 in |
J - Connector End Diameter |
N/A 2.00 in |
K - Distance btw. Shear Planes |
N/A 1.25 in |
L - Overall Length of Pin |
N/A 5.19 in |
MB - Length |
N/A 2.50 in |
MR - Length |
N/A 1.06 in |
N - Height of Anti-Rotation Plate |
N/A 1.75 in |
P - Width |
N/A 0.750 in |
Q - Anti-Rotation Plate - Clevis Pin |
N/A 1.50 in |
M - Anti-Rotation Plate - Rod End Clevis |
N/A 1.50 in |
S - Thickness |
N/A 0.25 in |
CW - Thickness |
N/A 0.63 in |
CB - Thickness |
N/A 1.25 in |
E - Length |
N/A 3.50 in |
Performance Specs
Overload without Zero Shift |
N/A 150% |
Overload without Failure |
N/A 300% (Minimum) |
Bridge |
N/A Full bridge 350 Ohm (Nominal) |
Excitation |
N/A 12 V AC (Maximum) 12 V DC (Maximum) |
Output Signal1 | N/A 2-mV/V (Nominal) 2-mV/V (Standardized Output) |
Non-Repeatability |
N/A ±0.15% FS (Nominal) |
Non-Linearity |
N/A ±0.50% FS (Nominal) |
Hysteresis |
N/A ±0.50% FS (Nominal) |
Service Temp Range |
N/A to 150 °F |
Temp Effects (on Zero) |
N/A 0.005% FS / °F (Nominal) |
Temp Effects (on Output) |
N/A 0.008% load / °F (Nominal) |
Zero Balance2 | N/A ±2% FS (Nominal) |
Calibration |
N/A CAL5-LO |
Electrical Specifications
Receptacle |
N/A PTIH-10-6P |
Mating Plug |
N/A PT06A-10-6S (SR) |
Function |
N/A Pin |
(+) Excitation |
N/A A |
(-) Excitation |
N/A D |
(+) Signal |
N/A B |
(-) Signal |
N/A C |
Cable |
N/A #20(26x34) AWG., rubber insulation, shielded, rubber jacket, 4-Conductor (Standard Cable) |
Function |
N/A Wire Code |
(+) Excitation |
N/A Red |
(-) Excitation |
N/A Black |
(+) Signal |
N/A Green |
(-) Signal |
N/A White |
General Information
N/A
Actuator/Hydraulic Cylinder Load Pins are strain gage transducers developed by Strainsert (U.S. Patent No. 3,695,096). They are manufacured utilizing the internal strain gage process perfected by Strainsert since 1960. We offer precision force measurement by simply replacing existing hydraulic cylinder load pins. |
- 1 Exact output provided with calibration data. (Standardized outputs are optional). In addition, Strainsert factory calibrations are intended to simulate installed conditions, however, it is recommended that an in-place calibration be performed to account for any installation, tolerance, and/or alignment influences affecting sensor measurement.
- 2 Prior to loading, it is necessary to initially/periodically null the zero load output to account for any residual offset.