Unit of Measure

Features

N/A All Tension Links can be fit with a permanently attached cable.

Model STL-13.5(SS)X shown.

Specifications

Dimensional Drawing

N/A
STL Series, Force Sensing Tension Links for Anchor and Chain Shackles
a1100.jpg

Load Capacity

N/A 1500 lb

Material

N/A Aluminum Alloy 7075-T6, Hard Coat Finish: Rockwell C-60

Connector Type

N/A Axial Connector

Shackle Size

N/A 5/16 Inch

A - Length

N/A 1/2 in

B - Width

N/A 7/16 in

C - Diameter

N/A 1 in

D - Diameter

N/A 0.384 in

E - Length

N/A 2-1/8 in

F - Length

N/A 1/4 in

G - Length

N/A 1-5/8 in

L - Overall Length

N/A 5 in

M - Length

N/A 4 in

R - Radius

N/A 1/2 in

T - Diameter

N/A 0.406 in

Weight

N/A 1 lb

Safety Factor

N/A 4.2

Performance Specs

Overload without Zero Shift

N/A 150%

Bridge

N/A Full bridge 350 Ohm (Nominal)

Excitation

N/A 12 V AC (Maximum) 12 V DC (Maximum)
Output Signal1 N/A 2-mv/V (Nominal)

Non-Repeatability

N/A 0.10% FS

Non-Linearity

N/A 0.25% FS

Hysteresis

N/A ±0.15% FS

Temp Effects (on Zero)

N/A 0.003% FS / °F

Temp Effects (on Output)

N/A 0.003% load / °F (Nominal)
Zero Balance2 N/A ±2% FS (Nominal)

Electrical Connection

N/A Receptacle or built-in cable

Static Overload

N/A 150% without zero or open shift

Electrical Specifications

Receptacle

N/A PT02H-10-6P

Mating Plug

N/A PT06A-10-6S (SR)

     Function

N/A Pin

     (+) Excitation

N/A A

     (-) Excitation

N/A D

     (+) Signal

N/A B

     (-) Signal

N/A C

Cable

N/A #20(26x34) AWG., rubber insulation, shielded, rubber jacket, 4-Conductor (Standard Cable)

     Function 

N/A Wire Code

     (+) Excitation 

N/A Red

     (-) Excitation 

N/A Black

     (+) Signal 

N/A Green

     (-) Signal 

N/A White

General Information

N/A The Strainsert Tension Links are superior performance sensors, for use in weighing and force measuringapplications.

Its sensing element consists of a strain gage bridge circuit internally installed in a small hole along itslongitudinal axis. This unique arrangement provides a most effective means for the protection and sealing of thestrain gage circuit while minimizing the adverse effects of extraneous torsional and flexural loads.

  • 1 Exact output provided with calibration data. (Standardized outputs are optional).
  • 2 Prior to loading, it is necessary to initially/periodically null the zero load output to account for any residual offset.