Unit of Measure

Specifications

Dimensional Drawing

N/A
TLS, TLN and TLNS Series, Force Sensing Tension Links with Threaded Ends
a1109.jpg

Load Capacity

N/A 100 KIPS

Material

N/A Stainless Steel 17-4, H-1025 (Standard)

Connector Type

N/A Connector Permanently Attached Cable

AN - Length

N/A 3-1/8 in

B - Width

N/A 2 in

C - Diameter

N/A 2-1/2 in

CC - Diameter

N/A 2-1/2 in

D - Diameter

N/A 1.614 in

E - Length

N/A 1-5/8 in

F - Length

N/A 3/4 in

G - Length

N/A 3 in

L - Overall Length

N/A 11-5/8 in

R - Radius

N/A 1/2 in

T - Thread Size

N/A 1-3/4-12N

Weight

N/A 10.1 lb

Safety Factor

N/A 2.7

Performance Specs

Overload without Zero Shift

N/A 150%

Bridge

N/A Full bridge 350 Ohm (Nominal)

Excitation

N/A 12 V AC (Maximum) 12 V DC (Maximum)
Output Signal1 N/A 2-mV/V (Nominal) 2-mV/V (Standardized Output)

Non-Repeatability

N/A 0.10% FS

Non-Linearity

N/A 0.25% FS

Hysteresis

N/A ±0.15% FS

Temp Effects (on Zero)

N/A 0.003% FS / °F (Nominal)

Temp Effects (on Output)

N/A 0.003% load / °F (Nominal)
Zero Balance2 N/A ±2% FS (Nominal)

Static Overload

N/A 150% without zero or open shift

Electrical Specifications

Receptacle

N/A PT02H-10-6P

Mating Plug

N/A PT06A-10-6S (SR)

     Function

N/A Pin

     (+) Excitation

N/A A

     (-) Excitation

N/A D

     (+) Signal

N/A B

     (-) Signal

N/A C

Cable

N/A #20(26x34) AWG., rubber insulation, shielded, rubber jacket, 4-Conductor (Standard Cable)

     Function 

N/A Wire Code

     (+) Excitation 

N/A Red

     (-) Excitation 

N/A Black

     (+) Signal 

N/A Green

     (-) Signal 

N/A White

General Information

N/A Strainsert Tension Links are superior performance sensors, for use in weighing and force measuring applications.

Its sensing element consists of a strain gage bridge circuit internally installed in a small hole along its longitudinal axis. This unique arrangement provides a most effective means for the protection and sealing of the strain gage circuit while minimizing the adverse effects of extraneous torsional and flexural loads.

Tension Links can be modified for underwater use.

  • 1 Exact output provided with calibration data. (Standardized outputs are optional).
  • 2 Prior to loading, it is necessary to initially/periodically null the zero load output to account for any residual offset.