Unit of Measure

Features

N/A

  • Low Profile, Rugged, Compact & Lightweight
  • Low Deflection
  • High Frequency Dynamic Load Sensing
  • Pressure Compensating
  • Sealed Strain Gages
  • Counterbored Mounting Holes
  • Low Sensitivity to Extraneous Loads
  • High Static Overload

Dimensional Drawing

Dimensional Drawing

N/A
Strainsert Compression Load Cell.jpg
a1044.jpg

Specifications

Load Capacity

N/A 7,500 lb

Type of Flat Load Cells

N/A Compression

Rated Output

N/A 2-mV/V (Nominal) 2-mV/V (Std. Output) 3-mV/V (Nominal) 3-mV/V (Std. Output)

Configuration

N/A Dual Bridge Single Bridge

Non-Linearity

N/A General Purpose ±0.25% F.S. Precision ±0.10% F.S.

Connector Type

N/A Connector Permanently Attached Cable

A - Diameter

N/A 21/32 in

B - Diameter

N/A 1-7/16 in

C - Diameter

N/A 2-1/2 in

D - Diameter

N/A 2-11/16 in

E - Length

N/A 3-23/32 in

F - Height

N/A 15/16 in

G - Width

N/A 2-13/16 in

H - Height

N/A 1-1/16 in

J - Length

N/A 1/16 in

K - Outside Diameter

N/A 1/4 in

k - Inside Diameter

N/A 5/32 in

Number of Hold Down Bolt Holes

N/A 4

L - Diameter

N/A 1-7/8 in

M - Length

N/A 1/32 in

N - Depth of Hole

N/A 5/32 in

Lifting Holes - Threads

N/A NONE

Lifting Holes - BC. Diameter

N/A NONE

Weight

N/A 1.2 lb

Material of Construction

N/A Alloy Steel

Performance Specs

Accuracy

N/A  

     Non-Linearity

N/A General Purpose ±0.25% FS Precision ±0.10% FS

     Hysteresis

N/A General Purpose ±0.15% FS Precision ±0.10% FS

     Non-Repeatability

N/A ±0.05% FS

Environmental

N/A  

     Compensated Range

N/A 60 to 150 ºF

     Effect on Zero

N/A ±0.0035% FS/°F

     Effect on Output

N/A ±0.0030% Load/°F (Nominal)

Electrical

N/A  

     Excitation Voltage

N/A 15V AC or DC (Maximum)

     Bridge Resistance

N/A 350 Ohms (Nominal)
     Zero Balance1 N/A ±2% FS (Nominal)

     Insulation Resistance

N/A 10,000 Megaohms (Minimum)

Mechanical

N/A  

     Safe Static Overload without Zero Shift

N/A 200%FS

     Safe Static Overload without Output Shift

N/A 200%FS

     Safe Static Overload without Structural Failure

N/A 250%FS

Electrical Specifications

Receptacle

N/A PT02H-10-6P

Mating Plug

N/A PT06A-10-6S (SR)

     Function

N/A Pin

     (+) Excitation

N/A A

     (-) Excitation

N/A D
     (+) Signal2 N/A B
     (-) Signal3 N/A C

Cable

N/A #20(26x34) AWG., rubber insulation, shielded, rubber jacket, 4-Conductor (Standard Cable)

     Function 

N/A Wire Code

     (+) Excitation 

N/A Red

     (-) Excitation 

N/A Black
     (+) Signal 4 N/A Green
     (-) Signal 5 N/A White
  • 1 Prior to loading, it is necessary to initially/periodically null the zero load output to account for any residual offset.
  • 2 The signal leads are reversed.
  • 3 The signal leads are reversed.
  • 4 The signal leads are reversed.
  • 5 The signal leads are reversed.