Features
N/A
|
Specifications
Load Capacity |
N/A 45 kN |
Type of Flat Load Cells |
N/A Universal Metric |
Rated Output |
N/A 2-mV/V (Nominal) 2-mV/V (Std. Output) 3-mV/V (Nominal) 3-mV/V (Std. Output) |
Configuration |
N/A Dual Bridge Single Bridge |
Non-Linearity |
N/A General Purpose ±0.25% F.S. Precision ±0.10% F.S. |
Connector Type |
N/A Connector Permanently Attached Cable |
Hole Type |
N/A Threaded Loading Hole Thru Hole |
A - Diameter |
N/A 27.0 mm |
B - Diameter |
N/A 46.0 mm |
C - Diameter |
N/A 81.0 mm |
D - Diameter |
N/A 85.7 mm |
E - Length |
N/A 113 mm |
F - Height |
N/A 23.8 mm |
G - Width |
N/A 74.6 mm |
H - Height |
N/A 25.4 mm |
K - Outside Diameter |
N/A 10.32 mm |
k - Inside Diameter |
N/A 7.14 mm |
Number of Hold Down Bolt Holes |
N/A 8 |
L - Diameter |
N/A 61.9 mm |
M - Length |
N/A 0.8 mm |
N - Depth of Hole |
N/A 9.5 mm |
T - Hole |
N/A 16.53 -0/+0.02 Thru Hole M16x1.5 |
Lifting Holes - Threads |
N/A NONE |
Lifting Holes - BC. Diameter |
N/A NONE |
Weight |
N/A 0.8 kg |
Material of Construction |
N/A Alloy Steel |
Performance Specs
Accuracy |
N/A   |
Non-Linearity |
N/A General Purpose ±0.25% FS Precision ±0.10% FS |
Hysteresis |
N/A General Purpose ±0.15% FS Precision ±0.10% FS |
Non-Repeatability |
N/A ±0.05% FS |
Environmental |
N/A   |
Compensated Range |
N/A 60 to 150 ºF |
Effect on Zero |
N/A ±0.0035% FS/°F |
Effect on Output |
N/A ±0.0030% Load/°F (Nominal) |
Electrical |
N/A   |
Excitation Voltage |
N/A 15V AC or DC (Maximum) |
Bridge Resistance |
N/A 350 Ohms (Nominal) |
Zero Balance1 | N/A ±2% FS (Nominal) |
Insulation Resistance |
N/A 10,000 Megaohms (Minimum) |
Mechanical |
N/A   |
Safe Static Overload without Zero Shift |
N/A 200%FS |
Safe Static Overload without Output Shift |
N/A 200%FS |
Safe Static Overload without Structural Failure |
N/A 250%FS |
Electrical Specifications
Mating Plug |
N/A PT06A-10-6S (SR) |
Function |
N/A Pin |
(+) Excitation |
N/A A |
(-) Excitation |
N/A D |
(+) Signal |
N/A B |
(-) Signal |
N/A C |
Cable |
N/A #20(26x34) AWG., rubber insulation, shielded, rubber jacket, 4-Conductor (Standard Cable) |
Function |
N/A Wire Code |
(+) Excitation |
N/A Red |
(-) Excitation |
N/A Black |
(+) Signal |
N/A Green |
(-) Signal |
N/A White |
General Information
N/A
Load Cells are strain gage transducers developed by Strainsert (U.S. Patent No. 3,695,096). They are manufacured utilizing the internal strain gage process perfected by Strainsert since 1960. |
- 1 Prior to loading, it is necessary to initially/periodically null the zero load output to account for any residual offset.