Unit of Measure

Features

N/A

  • Low Profile, Rugged, Compact & Lightweight
  • Low Deflection
  • High Frequency Dynamic Load Sensing
  • Pressure Compensating
  • Sealed Strain Gages
  • Counterbored Mounting Holes
  • Low Sensitivity to Extraneous Loads
  • High Static Overload

Dimensional Drawing

Dimensional Drawing

N/A
Universal Flat Load Cells
a1044.jpg

Specifications

Load Capacity

N/A 10,000 lb

Type of Flat Load Cells

N/A Universal

Rated Output

N/A 2-mV/V (Nominal) 2-mV/V (Std. Output) 3-mV/V (Nominal) 3-mV/V (Std. Output)

Configuration

N/A Dual Bridge Single Bridge

Non-Linearity

N/A General Purpose ±0.25% F.S. Precision ±0.10% F.S.

Connector Type

N/A Connector Permanently Attached Cable

Hole Type

N/A Threaded Loading Hole Thru Hole

A - Diameter

N/A 1-1/16 in

B - Diameter

N/A 1-13/16 in

C - Diameter

N/A 3-3/16 in

D - Diameter

N/A 3-7/16 in

E - Length

N/A 4-15/32 in

F - Height

N/A 15/16 in

G - Width

N/A 2-15/16 in

H - Height

N/A 1 in

K - Outside Diameter

N/A 13/32 in

k - Inside Diameter

N/A 9/32 in

Number of Hold Down Bolt Holes

N/A 8

L - Diameter

N/A 2-7/16 in

M - Length

N/A 1/32 in

N - Depth of Hole

N/A 3/8 in

T - Hole

N/A 5/8-18UNF-2B Thru Hole, 21/32"

Lifting Holes - Threads

N/A NONE

Lifting Holes - BC. Diameter

N/A NONE

Weight

N/A 1.7 lb

Mechanical Properties


FL10U_MP

Performance Specs

Accuracy

N/A  

     Non-Linearity

N/A General Purpose ±0.25% FS Precision ±0.10% FS

     Hysteresis

N/A General Purpose ±0.15% FS Precision ±0.10% FS

     Non-Repeatability

N/A ±0.05% FS

Environmental

N/A  

     Compensated Range

N/A 60 to 150 ºF

     Effect on Zero

N/A ±0.0035% FS/°F

     Effect on Output

N/A ±0.0030% Load/°F (Nominal)

Electrical

N/A  

     Excitation Voltage

N/A 15V AC or DC (Maximum)

     Bridge Resistance

N/A 350 Ohms (Nominal)
     Zero Balance1 N/A ±2% FS (Nominal)

     Insulation Resistance

N/A 10,000 Megaohms (Minimum)

Mechanical

N/A  

     Safe Static Overload without Zero Shift

N/A 200%FS

     Safe Static Overload without Output Shift

N/A 200%FS

     Safe Static Overload without Structural Failure

N/A 250%FS

Electrical Specifications

Receptacle

N/A PT02H-10-6P

Mating Plug

N/A PT06A-10-6S (SR)

     Function

N/A Pin

     (+) Excitation

N/A A

     (-) Excitation

N/A D

     (+) Signal

N/A B

     (-) Signal

N/A C

Cable

N/A #20(26x34) AWG., rubber insulation, shielded, rubber jacket, 4-Conductor (Standard Cable)

     Function 

N/A Wire Code

     (+) Excitation 

N/A Red

     (-) Excitation 

N/A Black

     (+) Signal 

N/A Green

     (-) Signal 

N/A White

General Information

N/A Load Cells are strain gage transducers developed by Strainsert (U.S. Patent No. 3,695,096). They are manufacured utilizing the internal strain gage process perfected by Strainsert since 1960. 

The structure is simple and compact, consisting of an inner loading hub and an outer supporting flange bridged smoothly by a uniformly continuous solid shear web avoiding structural stress risers.

Strain gages are installed and sealed inside small gage holes along the neutral axis of the web. Linearity and symmetry of output signal is obtained by equal straining of all shear gages in the bridge circuit.

Low deflection and high natural frequency are obtained, along with high resistance to extraneous forces. Mechanical and dynamic properties are fully tabulated.

  • 1 Prior to loading, it is necessary to initially/periodically null the zero load output to account for any residual offset.