The Strainsert 2-wire Loop Powered 4 to 20 mA Strain Gage Modules are specially designed compact, high performance strain gage analog signal conditioner modules. They are aimed at 350 Ohm sensor applications which require high measurement accuracy, resolution, and stability. The internal signal conditioner reduces interference in noisy environments and allows for longer cable runs. The module and sensor may be powered by a typical DC power supply. Outputs may be configured for either UniPolar or Bi-Polar operation.
The modules may be mounted inside of the Strainsert sensor body in either a single bridge, dual bridge, or biaxial configuration.
Contact Strainsert Engineering for assistance with custom solutions, systems integration, or software development.
The modules may be mounted inside of the Strainsert sensor body in either a single bridge, dual bridge, or biaxial configuration.
Contact Strainsert Engineering for assistance with custom solutions, systems integration, or software development.
Unit of Measure
Features & Benefits
N/A
Converts Bridge sensor output into 4 to 20 mA current loop. |
Specifications
Current Loop Supply |
N/A
Min: 7.5 Volts Typical: 24 Volts Max: 36 Volts |
Reverse Voltage Protection |
N/A Min: -100 Volts |
Operating Current |
N/A
Min: 3 mA Typical: 4-20 mA Max: 28 mA |
Operating Temperature |
N/A
Min: -40 °F Max: 185 °F |
Storage Temperature |
N/A
Min: -67°F Max: 257°F |
Bridge Resistance |
N/A Typical: 350 Ohns |
Bridge Excitation |
N/A
Min: .730 Volts Typical: .733 Volts Max: .740 Volts |
Bridge Sensitivity |
N/A
Min: 0.5 mV/V Typical: 2.0 mV/V Max: 6.0 mV/V |
Bandwidth |
N/A
Min: 0 Hz Max: 235 Hz |
Zero-Scale Temperature Stability |
N/A Max: 0.0100 %FS/°F |
Full-Scale Temperature Stability |
N/A Max: 0.0150 %FS/°F |
Electrical Isolation |
N/A Min: 10^10 Ohms at 50 VDC |
|