• The Model SCD1 is a series of signal conditioners which provide bridge excitation, amplification, span and balance controls and a choice of ±10 Vdc and/or 4-20 ma outputs. Primary input power is available in 120 Vac or a variety of Vdc voltage levels.

    The SCD1 can accommodate up to four channels with ±10 Vdc outputs or a maximum of 2 channels with 4-20 ma outputs.

    Standard SCD1 models are packaged in a NEMA-12 rated cabinet (NEMA-4X packages are available).

    Each input channel is connected via a six (6) pin receptacle (PT02A-10-6S)

    All output signals are provided at a terminal strip inside the signal conditioner cabinet . Each output signal has an individual terminal connection and each signal shares a single common return.

    Note: When ordering specify input sensitivity, and desired full scale output.

  • -Page-82-plnd2

    Indication is direct. No multipliers are required, thus avoiding ambiguous readings. Resolution is from 1 pound to 1000 pounds depending on the load capacity of the transducer. Alternate display units are available.

    Operation is extremely simple. For normal use only two controls are involved. Turn on the power switch, set no load balance, and begin reading applied loads.

    A calibration check function is included to provide a quick test of the transducer and instrument integrity.

    The readout system is fully contained in a cast metal case that is both rugged and durable.

    Power is provided by a set of rechargeable batteries. Batteries and a recharger with retractable 120 Vac power cord, are included within the housing.

    Battery power allows complete freedom of use and provides 5-10 hours of continuous use depending on transducer resistance. A ratiometric measuring technique prevents battery decay from degrading system accuracy.

    When battery voltage has decreased below a functional level, a visual display (flashing “:”) signals that recharging is needed.

    Recharging is done by withdrawing the line cord from its sealed compartment and plugging into a standard 110 Vac wall receptacle. Batteries are completely recharged overnight and can be left “on charge” indefinitely.

    Nickel Cadmium Batteries and Recharger included.
    Transducer cable connector: PT06A-10-6P(SR)
    Visual Display of Low Battery, Over Range, Polarity.

    For Full configuration click Request Information button.

  • -Page-84-plnx

    The PLNX- line of indicators are 2 and 4 channel versions with the same basic circuitry and performance features as the Model PLN-D2. Additional features include different instrument cases, and switching provisions for one to four channels which accommodate up to four transducers.

    Indication is direct. Resolution is from 1 pound to 1000 pounds, depending on full scale transducer capacity. Alternate display units are available.

    Simple operation. For normal use only three controls are involved: Turn on the power switch, select the channel, set the no load balance or tare reading to zero, and begin reading applied loads.

    A shunt calibration function provides a quick test of transducer and indicator integrity.

    The readout system is fully contained in a rugged and durable aluminum alloy case.

    Power is provided by a set of rechargeable batteries. Batteries and a recharger with a retractable 110 Vac or 220 Vac power cord, as specified, are included within the housing. In multichannel units, excitation voltage is maintained on all transducers independent of channel switching.

    Battery power allows complete freedom of use, and provides average of 5 – 10 hours continuous operation, depending on transducer resistance. A ratiometric measuring technique prevents degrading system accuracy due to battery decay.

    A visual display (Flashing “:”) signals that recharging is needed.

    Recharging is accomplished by withdrawing the recharge cord from its sealed compartment and plugging into a standard 110 Vac or 220 Vac, 60 or 50 Hz wall receptacle. 220 Vac applications will require plug adapters to be furnished locally by the customer. Batteries are completely recharged overnight and can be left “on charge” indefinitely.
    Readings can be obtained while the batteries are “on charge”. The instrument is effectively usable on either battery or line power.

    Nickel Cadmium Batteries and Recharger included.
    Transducer cable connector: PT06A-10-6P(SR)
    Visual Display of Low Battery, Over Range, Polarity.

    For Full configuration click Request Information button.

  • plnd4

    The Model PLND4 is a 4-1/2 digit indicator made for use with any full bridge strain gage type transducer. Indication is direct.

    No multipliers are required. Simple operation. For normal use only two controls are involved: turn on the power switch, set the no load balance or tare reading to zero, and begin reading applied loads.

    Alternate display units are available.

    A calibration check function is included to provide a quick test of the transducer and instrument integrity.

    The read out system is fully contained in a rugged and durable aluminum alloy case.

    Power is provided by a set of rechargeable batteries. Batteries and a recharger, operable on 110 Vac or 220 Vac, are included within the housing. A detachable power cord is included for recharging.

    Battery power provides 10 – 15 hours of continuous use depending on transducer bridge resistance. A ratiometric measuring system prevents battery decay from degrading system accuracy. When the battery voltage level drops to a preset value, a visible indicator signals the need for recharging.

    Nickel Cadmium Batteries and Recharger included.
    Transducer cable connector: PT06A-10-6P(SR)
    Visual Display of Low Battery, Over Range, Polarity.

    For Full configuration click Request Information button.

  • msi3550

    The 3550’s advanced electronics and simple interface make it easy to set up and operate. It is designed to perform effectively in tough environments.

    The 3550 features an oversized display (1.2” high LEDs) which can be read more than 50 feet away.

    The rugged stainless steel NEMA 4 enclosure is washdown safe for use in industrial and marine environments.

    Standard features include a peak capture function for stress analysis, RS-232 input/output, two programmable set-points, a built-in surge protection which ensures dependable operation and the capability to drive up to eight 350 ohm load cells.

    Optional features include the following: 6V Rechargeable battery with a 130 hour charge, two internal 10 amp relays, internal summing board, and an infrared remote controller.

    For Full configuration click Request Information button.

  • sjb-1

    The Strainsert SJB Series Summing Junction Boxes are for parallel averaging of 2 to 4 similar transducers. The standard SJB is available in a NEMA- 12 steel enclosure (NEMA-4X packages are optionally available). The NEMA-12 comes in both a connector style and a cord grip style (NEMA-4X available with cord grips only). Cord grips accept cables with diameters between 0.250” to 0.375” inches. The removal of a gasket-tight lid enables the user to make cable wire connections to screw type terminal blocks mounted on an internal circuit board. Overall enclosure dimension are 7.5” (L) x 4.25” (W) x 3.5” (H).